Input Rating | Power | 20KW | ||
Current | 0-500A | |||
Voltage | 0-150V | |||
CC Mode | Range | 0-50A | 0-500A | |
Resolution | 1mA | 10mA | ||
Accuracy | 0.1%+0.05%FS | 0.15%+0.1%FS | ||
CV Mode | Range | 0.1-19.999V | 0.1-150V | |
Resolution | 1mV | 10mV | ||
Accuracy | 0.03%+0.02%FS | 0.03%+0.02%FS | ||
CR Mode | Range | 0.03Ω -10K | 0.03Ω -5K | |
Resolution | 16 bit | 16 bit | ||
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | ||
CW Mode | Range | 0-7500W | 0-20KW | |
Resolution | 10mW | 100mW | ||
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | ||
V Measurement | Voltage | 0-19.999V | 0-150V | |
Resolution | 1mV | 10mV | ||
Accuracy | 0.015%+0.03%FS | 0.015%+0.03%FS | ||
Current Measurement | Current | 0-50A | 0-500A | |
Resolution | 1mA | 10mA | ||
Accuracy | 0.1%+0.05%FS | 0.15%+0.1%FS | ||
Power Measurement (Voltage and current input value >=10% full measurement) | Power | 100W | 20KW | |
Resolution | 1mW | 10mW | ||
Accuracy | 0.1%+0.1%FS | 0.2%+0.15%FS | ||
Battery Measurement | Battery Input:0.1-150V;Max. Measurement: Capacity=999AH; Resolution=0.1mA; Time Range=1S-16H | |||
Dynamic Test | Transition List: 0-25kHZ; 5A/uS;T1&T2:60uS-999S;Accuracy:+15% offset+10%FS | |||
CC soft-startup Time | 1mS;2mS;5mS;10mS;20mS;50mS;100mS;200mS;500ms;1000ms Accuracy:+15% offset+10%FS | |||
Short Circuit | Current(CC) | 55A | 550A | |
Voltage(CV) | 0V | |||
Resistance(CR) | 4mΩ | |||
Temperature | Operating | 0~40°C | ||
Nonoperating | –10°C~70°C | |||
Dimension | W*H*D(mm) | 700*2000*700 | ||
Weight | Kg | 370 | ||